22 General commands
6615-2220
+CIND – Indicator control
Description:
This command is used to read or set the values of ME indicators. If ME does not allow
setting of indicators or ME is not currently reachable, an error code is returned.
Syntax:
AT+CIND=[
Response syntax:
+CIND:
+CIND: (
Parameters:
Value, which shall be in range of corresponding
0:
indicator is OFF or in state that can be identified as “OFF” state
1: indicator is ON or in a state that is more substantial than “OFF” state
2: this value is more substantial than 1, and so on.
NOTE:
If the indicator is a simple ON/OFF style element, it has values 0 and 1.
"battchg":
battery charge level (0 – 5), not relevant
"signal":
signal quality (0 – 5)
"service":
service availability (0 – 1)
"message":
message received (0 – 1)
"call":
call in progress (0 – 1)
"roam":
roaming indicator (0 – 1)
"smsfull":
SMS memory storage status in the MT (0 – 1)
0: memory locations are available
1:
memory
full
2:
one SMS has been received in Service Center (SC) but the SMS
storage where this SMS tried to be stored is full.