208 Specific AT commands
6615-2220
+WATH – Hang-up command
Description:
This command is used by the application to disconnect the remote user, specifying a
release cause and the location. In the case of multiple calls, all calls are released (active,
on-hold and waiting calls).
Syntax:
AT+WATH=
Parameters:
Decimal value from 1 to 127 (see the table in appendix 18.4 “Failure Cause from GSM
04.08 recommendation)
Optional parameter (default value =0). values as defined in 04.08
0: user
1:
private network serving the local user
2:
public network serving the local user
3: transit
network
4:
public network serving the remote user
5:
private network serving the remote user
7: international
network
10: network beyond inter-working point
NOTE:
In order to have a “Normal Release”, use ATH command
Command example
Possible responses
Note
AT+WATH=31
OK
Ask for disconnection with
release cause=normal and
location=USER
AT+WATH=? +WATH:
(1-127),(0-5,7,10)
AT+WATH=17,2 OK
Ask for disconnection with
release cause=user busy
and location= public net-
work serving the local user