General commands 17
6615-2220
+CSIM – Generic SIM Access:
Description:
This command allows a direct control of the SIM by a distant application on the TE.
The
SIM
The user shall then take care of processing SIM information within the frame specified by
GSM as specified in GSM 11.11 (or 3GPP TS 51.011).
If operation mode is not allowed by the ME, +CME ERROR:
Between two successive +CSIM commands, there is no locking of the interface between
the SIM and the GSM application. Since in this situation some command types and param-
eters can modify wrong SIM's files, some operations, described below, are not allowed for
CSIM command. However, it is possible to process them with the CRSM command.
Syntax:
AT +CSIM=
Response:
+CSIM:
+CME ERROR:
Parameters:
Integer type. Length of the characters that are sent to TE in
or response). For command sent to TE, This value must be in the range
[10 – 522 else a CME_ERROR=3 is returned.
Hexadecimal type. Command passed on by the MT to the SIM in the
format as described in GSM 11.11 (or 3GPP TS 51.011) (hexadecimal
character format; refer +CSCS)
Second Byte Value not supported:
Due to the absence of locking, a CME_ERROR=3 is returned for the
following instructions (See CRSM commands):
D6
UPDATE
BINARY
DC
UPDATE
RECORD
32
INCREASE
44
REHABILITATE
04
INVALIDATE
88
RUN
GSM
ALGORITHM
20
VERIFY
CHV
24
CHANGE
CHV
26
DISABLE
CHV
28
ENABLE
CHV
2C
UNBLOCK
CHV
FA
SLEEP
C0
GET
RESPONSE