Wcbpwd – callback/secure access password – Westermo GDW-11 User Manual
Page 257

Callback security commands – only in GDW-12 257
6615-2220
Command example
Possible responses
Note
AT*WCB=2 OK
Callback
enabled
AT*WCB?
*WCB: 2
Check current value
OK
*WCBPWD – callback/secure access password
Description:
This command is used to store the password used in the callback and the secure access
functionality.
Three different passwords can be stored.
Syntax:
AT*WCBPWD1=
AT*WCBPWD2=
AT*WCBPWD3=
Parameters:
The password may contain any writable character. The maximum number of characters is
20.
See also the following commands: *wcbtab, *wcb, capawcbtime
Command example
Possible responses
Note
AT*WCBPWD1=qwerty
OK
Set password no 1
AT*WCBPWD2=asdfgh
OK
Set password no 2
AT*WCBPWD3=zxcvbnm
OK
Set password no 3
AT*WCBPWD1?
*WCBPWD1: qwerty
Current value
AT*WCBPWD3=-
OK
Delete the password