Westermo GDW-11 User Manual
Page 249

I/O commands – only in GDW-12 249
6615-2220
Defines if the establishment of service shall be retried, the time between retries is con-
trolled by register S7.
0:
NO, No retry, tries once to perform requested action
1:
RETRY, Retry infinitely to establish service according to current table entry.
2:
RETRY_3, Do 1 try and max 3 retries.
3:
NEXT_OK, If current service ends with OK the service specified by next table
entry will be trigged. If fail to perform/establish the current entry service the unit
will return to idle.
4:
NEXT_ERR, The unit will execute service specified by next table entry if fail to per-
form/establish current service.
NOTE:
If service according to current table entry terminates normally, the unit will return to idle
and wait for any new event trigger.
Timeout is used in Dial and Transparent I/O. The timeout is designed as an inactivity
timer and will be retrigged for each Data / I/O transfer. The timeout is the only normal
way to terminate Dial and Transparent I/O.
0:
The service will not be terminated
1 – 255: The timeout is specified in units of 10s.Valid values 1 – 255 *10 s
(10s – 2550s)
NOTE:
… Please see Table 1 for reference of state after termination by timeout.
… Setting a timeout for any other service than transparent I/O will not cause any fail-
ure but will not have any function.
Priority of the service specified.
0:
An existing connection will not be terminated Retries will be made according to
setting of
1:
The current connection will be terminated before the connection specified by serv-
ice is established.
The interpretation of this field depends on the service specified for the entry. The field
accepts 0 – 20 characters. The table below describes the different functions of
field in each different service.
DIAL:
Number to connect to
SMS:
Phone number of SMS receiver
TEXT:
Phone number of TEXT receiver, if left empty the TEXT is sent out on the
local DTE connection.
EMAIL: Reserved.