beautypg.com

Grandstream UCM6100 User Manual for 1.0.9.25 User Manual

Page 253

background image

Firmware Version 1.0.9.25

UCM6100 Series IP PBX User Manual

Page 252 of 303

digits, with a minimum length of 4 digits. Repetitive digits pattern

(such as 0000, 1111, 1234, 2345, and etc), or common digits pattern

(such as 111222, 321321 and etc) are not allowed to be configured as

password.

2. Password for extension registration, web GUI admin login, LDAP and

LDAP sync requires alphanumeric characters containing at least two

categories of the following, with a minimum length of 4 characters.
• Numeric digits
• Lowercase alphabet characters
• Uppercase alphabet characters
• Special characters

Enable Random Password

If enabled, random password will be generated when the extension is

created. The default setting is "Yes". It is recommended to enable it for

security purpose.

Disable Extension Range

If set to "Yes", users could disable the extension range

pre-configured/configured on the UCM6100. The default setting is "No".

Note:

It is recommended to keep the system assignment to avoid inappropriate

usage and unnecessary issues.

Extension Ranges

The default extension range assignment is:
• User Extensions: 1000-6299

User Extensions is referring to the extensions created under web

UI->PBX->Basic/Call Routes->Extensions page.

• Pick Extensions: 4000-4999

This refers to the extensions that can be manually picked from end

device when being provisioned by the UCM6100. There are two

related options in zero config page->Auto Provision Settings, "Pick

Extension Segment" and "Enable Pick Extension". If "Enable Pick

Extension" under zero config settings is selected, the extension list

defined in "Pick Extension Segment" will be sent out to the device

after receiving the device's request. This "Pick Extension Segment"

should be a subset of the "Pick Extensions" range here. This feature

is for the GXP series phones that support selecting extension to be

provisioned via phone's LCD.

• Auto Provision Extensions: 5000-6299

This sets the range for "Zero Config Extension Segment" which is the

This manual is related to the following products: