Figure 70: edit device – Grandstream UCM6100 User Manual for 1.0.9.25 User Manual
Page 110

Firmware Version 1.0.9.25
UCM6100 Series IP PBX User Manual
Page 109 of 303
Figure 70: Edit Device
A preview of the “Advanced” settings is shown in the above figure. There are five levels configurations
as described in (1) (2) (3) (4) (5) below, with priority from the lowest to the highest. The configurations
in all levels will take effect for the device. If there are same options existing in different level
configurations with different value configured, the higher level configuration will override the lower level
configuration.
(1) Global Policy
This is the lowest level configuration. The global policy configured in web UI->PBX->Zero
Config->Global Policy will be applied here. Clicking on “Modify Global Policy” to redirect to page
PBX->Zero Config->Global Policy.
(2) Global Templates
Select a global template to be used for the device and click on
to add. Multiple global
templates can be selected and users can arrange the priority by adjusting orders via
and
.
All the selected global templates will take effect. If the same option exists on multiple selected
global templates, the value in the template with higher priority will override the one in the template
with lower priority. Click on