Sample configuration – Grandstream UCM6100 User Manual for 1.0.9.25 User Manual
Page 167
Firmware Version 1.0.9.25
UCM6100 Series IP PBX User Manual
Page 166 of 303
SLA Station Options
Ring Timeout
Configure the time (in seconds) to ring the station before the call is
considered unanswered. No timeout is set by default. If set to 0, there will
be no timeout.
Ring Delay
Configure the time (in seconds) for delay before ringing the station when
a call first coming in on the shared line. No delay is set by default. If set to
0, there will be no delay.
Hold Access
This option defines the competence of the hold action for one particular
trunk. If set to “open”, any station could hold a call on that trunk or resume
one held session; if set to “private”, only the station that places the trunk
call on hold could resume the session. The default setting is “open”.
SAMPLE CONFIGURATION
1. On the UCM6100, go to web UI->Basic/Call Routes->Analog Trunks page. Create analog trunk or
edit the existing analog trunk. Make sure “SLA Mode” is enabled for the analog trunk. Once enabled,
this analog trunk will be only available for the SLA stations created under web UI->Basic/Call
Routes->SLA Station page.