background image

Pump/Dispenser Automatic Test

Page 78

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

4

Press PAYABLE until sale is selected in pull down menu.

5

Pay off sale (Press CASH, enter amount, ENTER).
Drawer will open. Close drawer.

6

Verify that the quantity displayed on the pump 1 register matches the quantity recorded on the
logger printout (cash price, price level 1 or level 0 if no level 1 is used).

7

Repeat steps

1

through

6

for all hose outlets.

Profit Point or SC III/POS WS - Prepay Pump Activation Test (optional when
using dual-stage solenoid valves)

1

Select pump 1 by pushing the Pump 1 key on the Profit Point.

2

Prepay the sale (PREPAY, 1 0 0, ENTER, START).
Drawer opens. Close drawer.

3

Use the pump handle to turn on pump 1 and squeeze the nozzle.
Pump product until it stops. Pump 1 will dispense product in fast flow until the slow cutoff is
reached, then the pump will dispense slowly until cutoff.

4

Verify that the total sale and gallon amount displayed on the pump 1 register matches the
volume and amounts you pre-selected on the Profit Point. Verify that the printout on the log
printer matches these totals.

5

Repeat steps

1

through

4

for all hose outlets.

Before Using Fuel Point

Before using Fuel Point, verify the following.

• Vehicle Modules are installed in accordance with C35699 Fuel Point Vehicle Module

Installation Manual.

• Vehicle Modules are programmed as explained in C35629 Vehicle Module Programming

Manual.

• The necessary site controller configurations have been made to FUELPT.BIN and

SYS_PAR.BIN, using C09326 CFN III Configuration Manual for Windows NT. The
configurations to FUELPT.BIN must match the factory-configuration of the vehicle
module programmer. If you do not know how your programmer is configured, call
GASBOY Technical Services for assistance.