Physical System Layout

Page 30

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Island Card Reader Assembly

1

Verify that the island card reader is installed to allow adequate clearance for system
maintenance. For systems with receipt printers or pedestal pump controls, a minimum of 18
inches is required between the post and any of the pumps or dispensers. This clearance meets
the NFPA 30A and NFPA 70 requirements.

2

Remove the two tamper-proof screws from either side of the black bezel, located on the front
of the island card reader head assembly. Unlock and lower the black bezel door.

3

Remove the six screws from the lower back side pedestal cover and remove the cover.

Note: No AC power should be present at TB6 in the island card reader head assembly.

4

Verify that the conduit and all system, pump, and dispenser wiring is installed according to the
specifications detailed in the Site Controller III Installation Manual. Non-compliance with
these specifications and the checks in the accompanying Start-Up Form could void the
warranty.

Pump Control Unit(s)

1

Verify that the pump control unit(s) are installed in an area protected from direct contact with
the weather according to the Site Controller III Installation Manual.

2

Verify that the conduit and all system, pump, and dispenser wiring is installed according to the
specifications detailed in the Site Controller III Installation Manual. Non-compliance with
these specifications and the checks in the accompanying Start-Up Form could void the
warranty.

7. CONDUIT

All Metal Conduit:

Indicate if all conduit is metal and not PVC. Circle Y for yes (all metal) or N for
no (not all metal conduit).

AC and DC is Separate
Conduit:

Indicate if all wiring is separated in the appropriate conduits according to the
conduit specifications and exceptions detailed in the SC III Installation Manual.
Circle Y for yes if all AC and DC wiring is in separate conduits. Circle N for no if
AC and DC wiring is combined in conduits where it should not be.

Wiring Neatness:

Indicate the overall neatness of the installer’s wiring. Is the appearance of the
wiring neat and orderly or is it very disorderly? Circle Good, Fair, or Bad.

Is shielded cable used?

Indicate if Gasboy C09655 or equivalent cable was used for communications
wiring. Circle Y for yes or N for no.