beautypg.com

Release, applications, and system data, Standalone profit point setup – Gasboy Site Controller III Start-Up User Manual

Page 109

background image

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Page 97

Start-up Commands

Release, Applications, and System Data

Note: Before trying this procedure, check the Site Manager’s Manual for the latest backup

routines and commands.

1

Have available several (minimum 4) blank formatted (high capacity) diskettes.

2

Type HARDBACK and press ENTER.
(You must run SYSBACK before running HARDBACK).

3

Follow the prompts to insert and label diskettes.

4

Store backups in a safe place!

Standalone Profit Point Setup

Because a demo MASTER.PLU file exists on the Profit Point, you must delete or rename this
file before loading department and item information.

1

To do this, access the Main Menu by turning the Manager’s key to MGR position, sign on (if
required), press SPEC FUNC, 0 and ENTER.
The Main Menu displays.

2

Press 0 and ENTER.
The DOS prompt (C:\POS>) displays.

3

To delete the MASTER.PLU file, type DEL MASTER.PLU and ENTER.

~ OR ~

To rename the file, type REN MASTER.PLU and the new name of the file and press ENTER.

4

Type menu 2 and press ENTER.

5

Press 0 and ENTER.
The Main Menu displays.
To return to POS mode, select 1 on the Main Menu and press ENTER.

6

Execute special function 37.
It may be necessary to sign on as a user with a higher permission level.

This command copies the site configuration (pumps, products, prices, etc.) and department
information (price, name, floor and ceiling prices, price override, etc.) to the Profit Point’s
MASTER.PLU file. Once this is done, you will have to load additional information into the
Profit Point. Use the forms from the

Site Information

section to help you define your data and

refer to MDE-4356 Profit Point Reference Manual for detailed instructions.