MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Page 27

Begin Start-Up Form

5. BREAKER NUMBERS

Indicate the breaker number for each of the following. All breakers pertaining to the system should be in
the OFF position.

Power conditioner:

AC Surge Protector:
(Profit Point)

Islander:
(N/A for SC III)

PCUs:
(pump control units)

ICRs:
(island card readers)

Hose/Brkr #:
(hose outlets 1 to 32)

Answer the following questions:

What components are on power conditioner? Fill in all that apply.

What components are on AC Surge Protector? Fill in all that apply.

Are all Gasboy components on same breaker? Answer Y or N.

Notes:
1. The AC Surge Protector Strip must be on its own separate breaker. The Site Controller, printer, and

monitor must be plugged into the same AC Surge Protector Strip. The Profit Point must also be plugged
into an AC Surge Protector Strip.

2. The optional power conditioner should be on the same breaker as the AC Surge Protector; however, if

this is not possible, it must be in the same phase of power as the AC Surge Protector breaker. The Site
Controller III, modem, standalone receipt printer, and console should be connected to the output of the
power conditioner, if used.

6. SYSTEM ENVIRONMENT

Describe the location and environment of each system component (for example, office, outside, air
conditioned, heated). Make sure the Site Controller III is well ventilated. Nothing should rest on the top of
the Site Controller or around its vents.