MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Page 59

Component Power-Up and Configuration

Remote Terminal Setup

The CFN remote port can be directly connected to a terminal. The terminal supplied by
GASBOY is a Link MC5 CRT terminal. If your site uses a remote terminal, install and
complete the setup of the terminal as specified in the manufacturer’s setup instructions. The
baud rate amd emulation mode must be set to match the Site Controller configuration.

Site Controller Configuration Changes

Although the system has already been configured and tested at the factory, you may need to
perform some configuration changes to match the site’s characteristics. Follow the instructions
in the Site Controller III Configuration Manual to make these changes.

The software for a CFN system with a 3-1/2" disk drive and a hard disk is supplied on the hard
disk and also on two backup 3-1/2" diskettes. During normal system use, any configuration
changes that you add to the CFN system are automatically place on the hard disk. To keep your
backup current, these changes must be copied onto the 3-1/2" backup diskette labeled DISK
#1.

The possible configuration programs are: SYS_PAR, READER, PUMP, CONSOLE, TABLE,
TRFMT, PERM, GATE, and FUELPT. Detailed information on these programs can be found
in the Configuration Manual. The following list contains items which may require changing
the site controller configuration.

• Use SYS_PAR parameters to change the Site ID #, Switch timeouts, and Pulser timeouts.
• Serial port configuration. Be sure all devices are plugged into the correct ports, and the

printer (if present) is set up according to the instructions provided earlier in this section.

• Use PUMP to check configuration to make sure correct pumps were set up at the factory.

Reassign pump control units if changes were made to previous pump types. If pulse rates
need to be changed, open S4 at the back of the Site Controller III boards (slide away from
loop connectors).

• If using a network, refer to the applicable Credit and Debit Card Networks Manual, for

specific network configuration considerations.

• If using Tokheim Dispenser Payment Terminals (DPTs), refer to DPT Instructions

available in C09146 Pump Interface Manual or contact GASBOY Technical Service.

• If using a CheckPoint or Profit Point, refer to the appropriate manuals listed in Section 1

for any special configuration considerations.

• If using Gate Reader, it is possible to configure the Prompts and Timeouts parameters.
• If using a tank monitoring system, it is possible to configure the add to inventory and log

delivery parameters.

• Use FUELPT to set the nozzle ring assignments and other Fuel Point parameters.
• If using Unitec Car Wash option, you can use the GATE program to set parameters, types,

and discounts.

Series 9800 Electronic Pumps and Dispensers

If you are using Series 9800 pumps and dispensers, there are switches that must be set
correctly to insure proper operation of your CFN system. See the Series 9800 Installation/
Operation Manual for details.