Page 45

Jumpers & Switch Settings

Diagnostic tests can be started by keeping the face of the ICR open and pressing the START
OVER key on the keypad.

Note: If you have the island receipt printer, see C08951 Star Receipt Printer Maintenance

Manual for switch settings and other information.

CPU PCB Jumper Settings

Jumpers on the CPU PCB are used for very basic configurations on the PCB and usually do
not need to be set in the field.
Note: When used with an optical reader, these jumpers can be removed or left at the factory

settings.

Reader Type

Disable Pumps PC Board Jumper Settings

The Disable Pumps PC Board is located within the head of the Island Card Reader. It is on the
left side directly below the board labeled RS-485 Protection Board. If the site’s island card
reader is equipped with an Disable Pumps button, check the K1 jumper on the Disable Pumps
PC Board. The Disable Pumps button attempts to shut off pumps regardless of the jumper
setting, but the setting determines the following:

• If the jumper is on and the site is configured for emergency stop, when the Disable Pumps

button is pressed, the pumps are shut down and the site logs an Emergency Stop condition.
It also shuts off pumps not connected to the RS-485 loop (that is, Tokheim pumps).

• If the jumper is off and Disable Pumps is pressed, the pumps just shut off and no message

is logged at the Site Controller.

Magnetic Card Reader

K4, 1 & 2

K4, 2 & 3

K5, 1 & 2

K5, 2 & 3

American Magnetics

Jumpered

Open

Jumpered

Open

Omron/Magtek

Open

Jumpered

Open

Jumpered