Pump/Dispenser Automatic Test
CheckPoint - Postpay Pump Activation Test (optional)
For more information, see the CheckPoint Reference Manual.
1
Use the pump handle to turn on pump 1.
CheckPoint beeps at set intervals and hose select LED flashes red for pump 1 on CheckPoint.
2
On the CheckPoint, select pump 1 and push START.
3
Dispense some product from pump 1, then turn pump 1 off by using the pump handle.
4
Pay off sale (Press CASH, enter amount, ENTER).
If cash drawer is present, it will open. Close drawer.
5
Verify that the quantity displayed on the pump 1 register matches the quantity recorded on the
system printout (cash price, price level 1 or level 0 if no level 1 is used).
6
Repeat steps
through
for all hose outlets.
CheckPoint - Prepay Pump Activation Test (optional when using dual-stage
solenoid valves)
1
Select Hose 1 on the CheckPoint by pushing the pump 1 key.
2
Select the prepay mode on the CheckPoint by pressing 1 0 0 PREPAY.
3
Press START on the CheckPoint to start pump 1.
Drawer opens. Close drawer.
4
Use the pump handle to turn on pump 1 and squeeze the nozzle.
Pump product until it stops. Pump 1 will dispense product in fast flow until the slow cutoff is
reached, then the pump will dispense slowly until cutoff.
5
Verify that the total sale and gallon amount displayed on the pump 1 register matches the
volume and amounts you pre-selected on the CheckPoint. Verify that the printout on the log
printer matches these totals.
6
Repeat steps
through
for all hose outlets controlled from the CheckPoint.
Profit Point or SC III/POS WS - Postpay Pump Activation Test (optional)
For more information, see the Profit Point Clerk’s Manual.
1
Turn the pump handle of pump 1.
Profit Point beeps three times at set intervals, indicating pump is offhook.
2
On the Profit Point, press OFF HOOK button, then START.
3
Dispense some product from pump 1; then turn pump off using pump handle.