beautypg.com

Figure 10-2: sample tank monitor printout – Gasboy Site Controller III Start-Up User Manual

Page 85

background image

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Page 73

Communication Tests

Figure 10-1: Sample of Creating TMTST.CMD File for TLS-350

4

At the command prompt (R* or [P:]*), type TMTST and press ENTER.
Once the command has completed, you should have a printout similar to the one shown in

Figure 10-2

.

Figure 10-2: Sample Tank Monitor Printout

5

Once you have verified the communications are working, type DEL TMTST.* and press
ENTER.
This deletes the TMTST files.

REC TMTST.CMD

Data?

*TM PORT TEST

PORT OPEN 2 BAUD 9600

PORT SEND ~01

PORT SEND 200

LOOP

PORT RECEIVE QUIET 2 FILE TMTST.DTA

IF ‘%E = 1

RETURN

PORT CLOSE

TY TMTST.DTA

.

P:

VEEDER-ROOT

TLS

TANK LEVEL SENSOR

----------

FEB 9, 2005

2:25 PM

TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE

1 UNLEADED 3858 34.60 0.0 72.9 1142

2 DIESEL 7331 66.01 1.0 60.2 2669