beautypg.com

Enable devices, Figure 12-26: example of e pc;i command, Figure – Gasboy Site Controller III Start-Up User Manual

Page 103

background image

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Page 91

Start-up Commands

Figure 12-23: Example of LO IN;C Command with Prompts

3

Type LO PLU;C to assign prices or price codes to products (

Figure 12-24

). See the Site

Manager’s Manual for details on the type of information defined here.

Figure 12-24: Example of LO PLU;C Command with Prompts

4

Use the E PRO command to set product attributes (

Figure 12-25

). See the Site Manager’s

Manual or the Pocket Reference for a list of product attributes.
Note: The LOad Fuel command automatically sets attribute 8 for that product. If you do not

want it to be attribute 8, you must disable it. See the Site Manager’s Manual, EN PRO
command.

Figure 12-25: Example of E PRO Command with Prompts

Enable Devices

1

Type E PC;I to enable the pump control unit (

Figure 12-26

).

Figure 12-26: Example of E PC;I Command

2

Type E PU;I to enable all the pumps (

Figure 12-27

).

R* LO IN;C

Product? 1

Quantity? 400

Reorder level? 100

R*

R* LO PLU;C

Product? 1

Price? 1.05

Product? 2

Price? 1.50

Product?

R*

R* E PRO

Product code? 11

Type? 4

R*

R* E PC;I

R*