Page 48

background image

Jumpers & Switch Settings

Page 36

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

Switches, S1 and S2

Switch S1 - PC IRQ
Indicates the interrupt. Only one can be selected. SC3.EXE assumes interrupt 10. No other
device can use this interrupt.

Switch S2 - PC Address
Sets PC Dual RAM address. SC3.EXE currently assumes D0000.

Switch SW3 - Default Sign-On
Position 4 defaults to Open; Closed Normal setting.

Switch SW4 - Weights and Measures Switch
Set to Open for enable; Closed for disable.

K8

Rx clock from synchronous modem
(DB25-15)

1 - 2 to connect

K9

ETC output to synchronous modem
(DB25-24)

1 - 2 to connect

K10

Tx clock input from synchronous
modem (DB25-17)

1 - 2 to connect

K11

EPROM type

2 - 3 for 27256/25128

K12

EPROM type

2 - 3 for 27256/25128

Switch

Function

Default

S1-1

IRQ-15

Open

S1-2

IRQ-12

Open

S1-3

IRQ-11

Open

S1-4

IRQ-10

Closed

Address

Switch

Address

Switch

1

2

3

4

1

2

3

4

C0000

C

C

C

C

D6000

O

C

C

C

C3000

C

C

C

O

D9000

O

C

C

O

C6000

C

C

O

C

DC000

O

C

O

C

C7000

C

C

O

O

DF000

O

C

O

O

CC000

C

O

C

C

E0000

O

O

C

C

CF000

C

O

C

O

E3000

O

O

C

O

D0000

C

O

O

C

E6000

O

O

O

C

D3000

C

O

O

O

E9000

O

O

O

O

Jumper

Function

Setting