Component Power-Up and Configuration
Page 58
MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005
Okidata Printer/Logger
The following printer switch settings are applicable for the Okidata 184 printer when
connected to a GASBOY CFN Fuel Management System. This document is not intended to be
a complete reference for the printer. Consult the documentation that came with the printer.
To prepare the Okidata 184 printer for operation with your GASBOY Fuel Management
System, perform the following steps. Install and complete the setup of the printer as specified
in the manufacturer’s setup instructions. Then set up the switches as follows:
SW2
1
Take the printer offline by pressing SELECT. The SELECT light should go off.
2
Position the print head at the top of the paper and press the TOF SET button.
3
Put the printer back online by pressing SELECT. The SELECT light should go on.
4
Press the MODE button until the light next to HSD is lit.
5
Press the PITCH button until the light next to 17 is lit.
Note: Pitch may be set to a lower number (resulting in larger print) if transactions are less
than 132 characters.
SW1-1
ON
Parity: Odd
SW1-2
ON
Parity: Without
SW1-3
ON
Data bits: 8
SW1-4
OFF
Protocol: XON/XOFF
SW1-5
ON
Test select: Circuit
SW1-6
ON
Mode select: Print
SW1-7
ON
Busy line selection: DTR - Pin 20
SW1-8
ON
Busy line selection: DTR - Pin 20
Baud Rate
SW2-1
SW2-2
SW3-3
9600
OFF
ON
ON
2400
OFF
OFF
ON
1200
ON
ON
OFF
300
ON
OFF
OFF
Note: Any change to the baud rate must also be changed on the Link Terminal
Communications Setup screen, Aux Baud parameter.
SW2-4
ON
DSR output signal: Active
SW2-5
ON
Buffer threshold: 32 bytes
SW2-6
OFF
Busy signal timing: 1 second (minimum)
SW2-7
ON
DTR signal: Space after power on
SW2-8
OFF
Not used