Start-up Commands
Card Authorizations, Limitations
1
Type LO A;IC to load the fuel codes allowed for each authorization number (
).
For initial start-up, assign fuel codes to all authorization codes, beginning with code 1 and
continuing through code 99. While up to 99 codes are possible, most systems use much less;
the default is 20.
See the Site Manager’s Manual for an explanation of authorization for non-fuel products.
Figure 12-18: Example of LO A;IC Command with Prompts
2
Type LO LI;IC to assign the maximum fuel quantities to be used in limitation codes (
For initial start-up, assign quantities to all codes, beginning with code 0 and continuing
through code 99. While up to 99 codes are possible, most systems use much less. The default
is 20.
Note: If the number in LIMIT? is preceded by a dollar sign, the value is in dollars ($20 in the
first example). If the LIMIT? is typed alone, the value is assumed to be gallons (25
gallons in the second example).
Figure 12-19: Example of LO LI;IC Command with Prompts
3
Use the LO CR;IC command to load any cron commands (
Cron commands instruct the Site Controller III to execute commands or recorded files at a
specified time or when certain events (such as a system crash) occur. Some cron commands
may already be loaded. If you wish to keep them, do not use the ;I option. Cron commands are
discussed fully in the Site Manager’s Manual.
Note: CRASH.CMD and SWEEPER.CMD are automatically loaded by the AUTOEXEC. A
backup of the system must be present as SYSBACK.DTA on the root directory.
SYSBACK is discussed further later in this section.
R* LO A;IC
Auth # ? 1
Product code? 1
Product code? 2
Product code?
Auth # ? 2
Product code? 3
Product code?
Auth # ?
R*
R* LO LI;IC
Limitation code? 1
Limit? $20
Limitation code? 2
Limit? 25
Limitation code?
R*