Interlogix NS3550-2T-8S User Manual User Manual
Page 87
IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
87
•
Condition
As Digital Input:
Allows user to select High to Low or Low to High. This means a signal received
by system is from High to Low or From Low to High. It will trigger an action that
logs a customize message or issue the message from the switch.
As Digital Output:
Allows user to select High to Low or Low to High. This means
that when the
switch is power-failed or port-failed, then system will issue a High or
Low signal to an external device such as an alarm.
•
Event Description
Allows user to set a customized message for Digital Input function alarming.
•
Event
As Digital Input:
Allows user to record alarm message to System log, syslog or issues out via
SNMP Trap or SMTP.
As default SNMP Trap and SMTP are disabled, please enable them first if you
want to issue alarm message via them.
As Digital Output:
Allows user to monitor an alarm from port failure, power failure, Digital Input 0
(DI 0) and Digital Input 1(DI 1) which means if Digital Output has detected these
events, then Digital Output would be triggered according to the setting of
Condition.
• Power Alarm
Allows user to choose which power module that needs to be monitored.
•
Port Alarm
Allows user to choose which port that needs to be monitored.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.