beautypg.com

1 system command, System configuration, System log configuration – Interlogix NS3550-2T-8S User Manual User Manual

Page 354

background image

IFS NS3552-8P-2S AND NS3550-2T-8S User Manual

354

6.1 System Command

System Configuration

Description:

Show system configuration.

Syntax:

System Configuration [all] []

Parameters:

all : Show all switch configuration, default: Show system configuration

port : Show switch port configuration

: Port list or 'all', default: All ports

Example:

To display system information:

NS3552-8P-2S:/>System configuration
System Contact :
System Name : NS3552-8P-2S
System Location :
MAC Address :

9c-f6-1a-02-7d-70

Temperature : 27.0 C - 80.6 F
System Time : 1970-01-01 Thu 03:28:50+00:00
System Uptime : 03:28:50
Software Version: 1.0b121221
Software Date : 2012-12-21T14:58:31+0800
Previous Restart: Cold
Power Status : PWR1 :ON,PWR2 :OFF
NS3552-8P-2S:/>

System Log Configuration

Description:

Show system log configuration.

Syntax:

System Log Configuration

This manual is related to the following products: