4.15.4 Cable Diagnostics
This page is used for running the Cable Diagnostics.
Press to run the diagnostics. This will take approximately 5 seconds. If all ports are selected, this can take approximately 15
seconds. When completed, the page refreshes automatically, and you can view the cable diagnostics results in the cable status
table. Note that Cable Diagnostics is only accurate for cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running cable diagnostic. Therefore, running cable diagnostic on a 10 or 100
Mbps management port will cause the switch to stop responding until VeriPHY is complete. The ports belong to the currently
selected stack unit, as reflected by the page header. The VeriPHY Cable Diagnostics screen in
Figure 4-15-4
appears.
Figure 4-15-4: VeriPHY Cable Diagnostics Page Screenshot
The page includes the following fields:
Object
Description
•
Port
The port where you are requesting Cable Diagnostics.
Please be noticed that it is only affect to copper port, not fiber port.
•
Cable Status
Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.
Buttons
: Click to run the diagnostics.