Interlogix NS3550-2T-8S User Manual User Manual
Page 52

IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
52
S30-2SLC-70
SFP, LC Connector, Single Mode, Gigabit, 2 fiber,1550nm/1550nm, 70km
S30-RJ
SFP, RJ-45, Gigabit, 100m
S35-2MLC
SFP, LC Connector, Multi-Mode, Gigabit, 2 fiber,850nm/850nm, 550m,
Hardened -40~75°C
S35-2SLC-10
SFP, LC Connector, Single Mode, Gigabit, 2 fiber,1310nm/1310nm, 10km,
Hardened -40~75°C
S35-2SLC-30
SFP, LC Connector, Single Mode, Gigabit, 2 fiber,1310nm/1310nm, 30km,
Hardened -40~75°C
S35-2SLC-70
SFP, LC Connector, Single Mode, Gigabit, 2 fiber,1550nm/1550nm, 70km,
Hardened -40~75°C
Fast Ethernet SFP Transceiver Modules
Error! Not a valid link.
1. It is recommended to use IFS SFPs on the Industrial Managed Switch. If you insert an SFP
transceiver that is not supported, the Industrial Managed Switch will not recognize it.
2. Please choose the SFP transceiver which is appropriate for the operating environment.
1000Base-SX/LX:
Before connecting the other switches, workstation or media converter.
1.
Make sure both sides of the SFP transceiver are with the same media type, for example, 1000Base-SX to 1000Base-SX,
1000Bas-LX to 1000Base-LX.
2.
Check the fiber-optic cable type that matches the SFP transceiver model.
To connect to 1000Base-SX SFP transceiver, use the multi-mode fiber cable with one side being the male duplex LC
connector type.
To connect to 1000Base-LX SFP transceiver, use the single-mode fiber cable with one side being the male duplex LC
connector type.
Connect the fiber cable
1.
Attach the duplex LC connector on the network cable into the SFP transceiver.
2.
Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a media
converter.
3.
Check the LNK/ACT LED of the SFP slot on the front of the Industrial Managed Switch. Ensure that the SFP transceiver
is operating correctly.
100Base-FX:
Before connecting the other switches, workstation or media converter.
1.
Make sure both sides of the SFP transceiver are with the same media type or WDM pair; for example, 100Base-FX to
100Base-FX, 100Base-BX20-U to 100Base-BX20-D.
2.
Check the fiber-optic cable type that matches the SFP transceiver model.
To connect to MFB-FX SFP transceiver, use the multi-mode fiber cable with one side being the male duplex LC
connector type.
To connect to MFB-F20/F40/F60/FA20/FB20 SFP transceiver, use the single-mode fiber cable with one side being the
male duplex LC connector type.
Connect the fiber cable
1.
Attach the duplex LC connector on the network cable into the SFP transceiver.
2.
Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a media
converter.