IFS NS3552-8P-2S AND NS3550-2T-8S User Manual

326

4.17 Loop Protection

This page allows the user to inspect the current Loop Protection configurations, and possibly change them as well.

4.17.1 Configuration

This page allows the user to inspect the current Loop Protection configurations,

Figure 4-17-1: Loop Protection Configuration Page Screenshot

The page includes the following fields:

General Settings:

Object

Description

Enable Loop
Protection

Controls whether loop protections is enabled (as a whole).

Transmission Time

The interval between each loop protection PDU sent on each port. Valid values
are 1 to 10 seconds.

Shutdown Time

The period (in seconds) for which a port will be kept disabled in the event of a loop
is detected (and the port action shuts down the port). Valid values are 0 to 604800
seconds (7 days). A value of zero will keep a port disabled (until next device
restart).