beautypg.com

2 rmon alarm status – Interlogix NS3550-2T-8S User Manual User Manual

Page 331

background image

IFS NS3552-8P-2S AND NS3550-2T-8S User Manual

331

Buttons

: Click to add a new community entry.

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.

4.18.2 RMON Alarm Status

This page provides an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm table, default being 20,

selected through the "entries per page" input field. When first visited, the web page will show the first 20 entries from the

beginning of the Alarm table. The first displayed will be the one with the lowest ID found in the Alarm table; screen in

Figure

4-18-2

appears.

Figure 4-18-2: Port Statistics Overview page screenshot

The page includes the following fields:

Object

Description

ID

Indicates the index of Alarm control entry.

Interval

Indicates the interval in seconds for sampling and comparing the rising and falling
threshold.

Variable

Indicates the particular variable to be sampled

Sample Type

The method of sampling the selected variable and calculating the value to be
compared against the thresholds.

Value

The value of the statistic during the last sampling period.

Startup Alarm

The alarm that may be sent when this entry is first set to valid.

Rising Threshold

Rising threshold value.

Rising Index

Rising event index.

Falling Threshold

Falling threshold value.

Falling Index

Falling event index.

Buttons

Auto-refresh

: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.

This manual is related to the following products: