Mep peer mep, Mep continuity check configuration, Mep loss measurement configuration – Interlogix NS3550-2T-8S User Manual User Manual
Page 513
IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
513
MEP Peer MEP
Description:
MEP Peer MEP id configuration.
Syntax:
MEP peer MEP [
Parameters:
enable|disable: enable/disable
MEP Continuity Check Configuration
Description:
MEP Continuity Check configuration
'prio' is the priority (PCP) of transmitted CCM frame
'300s|100s|10s|1s|6m|1m|6h' is the number of CCM frame pr. second.
Syntax:
MEP cc config [
Parameters:
300s|100s|10s|1s|6m|1m|6h: OAM period (100s -> 100 PDU pr. second)
enable|disable : enable/disable
MEP Loss Measurement Configuration
Description:
MEP Loss Measurement configuration
'prio' is the priority (PCP) of transmitted LM frame
'uni|multi' is selecting uni-cast or multi-cast transmission of LM frame
'single|dual' is selecting single-ended (LMM) or dual-ended (CCM) LM
'10s|1s|6m|1m|6h' is the number of LM frame pr. second