beautypg.com

Mep peer mep, Mep continuity check configuration, Mep loss measurement configuration – Interlogix NS3550-2T-8S User Manual User Manual

Page 513

background image

IFS NS3552-8P-2S AND NS3550-2T-8S User Manual

513

MEP Peer MEP

Description:

MEP Peer MEP id configuration.

Syntax:

MEP peer MEP [] [] [] [enable|disable]

Parameters:

: Instance number

: This MEP id (0-0x1FFF)

: MAC address ('xx-xx-xx-xx-xx-xx' or 'xx.xx.xx.xx.xx.xx' or 'xxxxxxxxxxxx', x is a hexadecimal digit)

enable|disable: enable/disable

MEP Continuity Check Configuration

Description:

MEP Continuity Check configuration

'prio' is the priority (PCP) of transmitted CCM frame

'300s|100s|10s|1s|6m|1m|6h' is the number of CCM frame pr. second.

Syntax:

MEP cc config [] [] [300s|100s|10s|1s|6m|1m|6h] [enable|disable]

Parameters:

: Instance number

: OAM PDU priority

300s|100s|10s|1s|6m|1m|6h: OAM period (100s -> 100 PDU pr. second)

enable|disable : enable/disable

MEP Loss Measurement Configuration

Description:

MEP Loss Measurement configuration

'prio' is the priority (PCP) of transmitted LM frame

'uni|multi' is selecting uni-cast or multi-cast transmission of LM frame

'single|dual' is selecting single-ended (LMM) or dual-ended (CCM) LM

'10s|1s|6m|1m|6h' is the number of LM frame pr. second

This manual is related to the following products: