Dido do power alarm, Dido fault act – Interlogix NS3550-2T-8S User Manual User Manual
Page 598

IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
598
DIDO DO Power Alarm
Description:
Set or show the system digital output0/1 power alarm.
Syntax:
DIDO Do_pwr_alr [first|second] [dc1|dc2] [enable|disable]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
dc1 : DC power 1
dc2 : DC power 2
(default: Set or show digital output/fault alarm 0/1 power_fail)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
DIDO Fault Act
Description:
Set or show the system fault alarm action.
Syntax:
DIDO Fault_act [port|power] [enable|disable]
Parameters:
port : port fail
power : power fail
DI1 : DI1 trigger
DI2 : DI2 trigger
(default: Set or show digital output/fault alarm 0/1 action)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)