Interlogix NS3550-2T-8S User Manual User Manual
Page 243
IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
243
RADIUS-assigned).
This option is only available for single-client modes, i.e.
• Port-based 802.1X
• Single 802.1X
For trouble-
shooting VLAN assignments, use the "Monitor→VLANs→VLAN
Membership and VLAN Port" pages. These pages show which modules have
(temporarily) overridden the current Port VLAN configuration.
RADIUS attributes used in identifying a VLAN ID:
VLAN ID in an Access-Accept packet. The following criteria are used:
- The Tunnel-Medium-Type, Tunnel-Type, and Tunnel-Private-Group-ID
attributes must all be present at least once in the Access-Accept packet.
- The switch looks for the first set of these attributes that have the same
Tag value and fulfill the following requirements (if Tag == 0 is used, the
Tunnel-Private-Group-ID does not need to include a Tag):
- Value of Tunnel-Medium-Type must be set to "IEEE-802" (ordinal 6).
- Value of Tunnel-Type must be set to "VLAN" (ordinal 13).
- Value of Tunnel-Private-Group-ID must be a string of ASCII chars in the
range '0' - '9', which is interpreted as a decimal string representing the
VLAN ID. Leading '0's are discarded. The final value must be in the
range [1; 4095].
• Guest VLAN Enabled
When Guest VLAN is bot
port, the switch considers moving the port into the Guest VLAN according to the
rules outlined below.
This option is only available for EAPOL-based modes, i.e.:
• Port-based 802.1X
• Single 802.1X
• Multi 802.1X
For trouble-shooting VLAN assignments, use the "Monitor
→VLANs→VLAN
Membership and VLAN Port" pages. These pages show which modules have
(temporarily) overridden the current Port VLAN configuration.
Guest VLAN Operation:
When a Guest VLAN enabled port's link comes up, the switch starts transmitting
EAPOL Request Identity frames. If the number of transmissions of such frames
exceeds
meanwhile; the switch considers entering the Guest VLAN. The interval between
transmissions of EAPOL Request Identity frames is configured wit
Timeout. If
placed in the Guest VLAN. If disabled, the switch will first check its history to see if
an EAPOL frame has previously been received on the port (this history is cleared
if the port link goes down or the port'
will be placed in the Guest VLAN. Otherwise it will not move to the Guest VLAN,
but continue transmitting EAPOL Request Identity frames at the rate given by
EAPOL Timeout.
Once in the Guest VLAN, the port is considered authenticated, and all attached
clients on the port are allowed access on this VLAN. The switch will not transmit
an EAPOL Success frame when entering the Guest VLAN.
While in the Guest VLAN, the switch monitors the link for EAPOL frames, and if
one such frame is received, the switch immediately takes the port out of the Guest
VLAN and starts authenticating the supplicant according to the port mode. If an
EAPOL frame is received, the port will never be able to go back into the Guest
VLAN if the "Allow Guest VLAN if EAPOL Seen" is disabled.
• Port State
The current state of the port. It can undertake one of the following values:
Globally Disabled: NAS is
Link Down: NAS is globally enabled, but there is no link on the port.
Authorized: The port is i
mode and the supplicant is authorized.
Unauthorized: The port is i
mode and the supplicant is not successfully authorized by the RADIUS
server.
X Auth/Y Unauth: The port is in a multi-supplicant mode. Currently X