Measuring mode – KEYENCE LS-7600 User Manual
Page 95

5-33
Chapter 5 Function Settings
5
Measuring Mode
The Measuring mode allows the LS-7600 Series to capture and hold measured values.
Setting Range
The LS-7600 Series has 11 types of Measuring modes. Refer to the following informa-
tion for the outline of each mode.
Normal
Sampling time
Measured value
Max. value
The measured
value is displayed
and output as it
occurs.
Sampling time
Measured
value
Minimum value
Sampling time
Measured value
Maximum-to-
minimum value
Max. value
Minimum value
Maximum-to-
minimum value
Peak Hold
The maximum
value during the
period specified
is displayed and
output.
Bottom Hold
The minimum
value during the
period specified
is displayed and
output.
Peak-to-peak Hold
The maximum-to-
minimum value
during the period
specified is
displayed and
output.
Average Hold
The average
value during the
period specified
is displayed and
output.
Auto Peak Hold
The maximum
value measured
is displayed and
output as it
occurs.
Auto Bottom Hold
The minimum
value measured
in displayed and
output as it
occurs.
Auto Peak-to-peak Hold
The maximum-to-
minimum value
measured is
displayed and
output as it occurs.
Sample Hold 1
The instantaneous
value at the time
specified is
displayed and
output.
Sample Hold 2
The value
measured during
the period specified
is displayed and
output.
Self-timing Hold
The measured value is displayed and
output with no external timing input (i.e.,
timing input). The self-timing period is
adjustable between 1 and 9,999 ms.
Self-timing value
Sampling time
ST
time
Workpiece insertion
Synchronous input
(timing input)
Sample Hold 1
value
Synchronous input
(timing input)
Sample hold 2
value
Sampling time
Sampling time
Measured value
Average
value