Mode specifications, Run mode, Program mode – KEYENCE LS-7600 User Manual
Page 201: Others, Chapter 9 specifications

9-7
Chapter 9 Specifications
9
Mode Specifications
■
RUN Mode
Status
Measured value display
Output
RS-232C
Numeric display Comparator display 5-level discrimination WAITING STROBE Analog output BCD ALARM FUNCTION Reception Response
Measuring
Positive-
side range
over
+FFFFFFF
Reference value: HI
Threshold: HH
OFF
+All
digits: F
OFF
Value
Measured value Comparator output Comparator output
OFF
Value
OFF
Negative
side range
over
–FFFFFFF
Reference value: LO
Threshold: LL
OFF
–All
digits: F OFF
Reset processing
– – – – – – –
OFF
OFF
ON
OFF
Comparator waiting voltage All digits: B OFF
Error
Error-0
None
OFF
OFF
OFF
+
10.5
+All
digits: B
ON
OFF
Error
response
Comparator
waiting
– – – – – – –
OFF
OFF
ON
Depends
on
measuring
mode
+All
digits: B
OFF
Not
synchronized
with set
conditions
O
O
O
O
O
O
O
O
O
O
O
Voltage according to
the measured value.
+10.5 V on the
positive side and
–10.5 V on the
negative side if the
voltage range is not
within
±
10 V.
Reference value: HI
Threshold: HH
Reference value: LO
Threshold: LL
Comparator
waiting
voltage
■
PROGRAM Mode
Status
Measured value display
Output
RS-232C
Numeric display
Comparator display 5-level discrimination WAITING STROBE Analog output
BCD ALARM FUNCTION Reception Response
Tolerance
setting
Same as the condition in
RUN mode operation
None
None
None
None
None
Same as the condition in RUN mode operation
Error
response
O
OFF
ON
OFF
Comparator
waiting voltage
All
digits: B
OFF
OFF
Area setting
Other than
level setting
Same as the condition in RUN mode operation
Error
response
O
Level
setting
Environment setting
Other than
LED inspection
LED
inspection
Same as the condition in
RUN mode operation
Same as the condition in
RUN mode operation
Optical waveform
and threshold
Error
response
O
Output setting
Same as the condition in RUN mode operation
Same as the condition in RUN mode operation
Same as the condition in RUN mode operation
Error
response
O
Calibration
setting
Each area
value
OFF
ON
OFF
Optical
waveform
All
digits: B
OFF
OFF
None
Error
response
O
Expansion
setting
Error
response
O
Error
response
O
Error
response
O
Same as the condition in
RUN mode operation
None
None
None
None
None
None
None
■
Others
Status
Measured value display
Output
RS-232C
Numeric display
Comparator display 5-level discrimination WAITING STROBE Analog output
BCD
ALARM FUNCTION Reception Response
Power-ON reset
processing
- - - - - - -
None
OFF
OFF
OFF
0V
+All
digits: 0
ON
OFF
Error
response
O
• The LS-7600 Series will be reset if the LS-7600 Series is set to RUN mode from
PROGRAM mode.
• After a program number change is made, the LS-7600 Series will be reset on comple-
tion of auto zero processing.
• The LS-7600 Series will be reset if a set value change is made over RS-232C.
• If an ERROR-0 occurs during power-ON reset processing, the analog output will be
set to 0 V and all the digits of the BCD output will be added with 0.