beautypg.com

Measuring head, Optional accessories – KEYENCE LS-7600 User Manual

Page 197

background image

9-3

Chapter 9 Specifications

9

Measuring Head

LS-7010M

0.04 to 6mm

0.04mm

60±5mm

Approx. 7mm

±0.5µm (

❈1)

±0.06µm (

❈2)

Transmitter: Approx. 140 g

Emitter: Approx. 380 g

Base: Approx. 220 g

LS-7070M

0.5 to 65 mm

0.5 mm

250±50 mm

Approx. 69 mm

±3µm (

❈5)

±0.2µm (

❈6)

Transmitter: Approx. 540 g

Emitter: Approx. 770 g

Base: Approx. 660 g

LS-7030M

0.3 to 30mm

0.3mm

160±40mm

Approx. 33 mm

±2µm (

❈3)

±0.15µm (

❈4)

Transmitter: Approx. 420 g

Emitter: Approx. 570 g

Base: Approx. 430 g

Model

Measuring range

Minimum detectable object

T-to-R distance

Light source

CCD scanning range

Measurement position accuracy

Repeating accuracy

Sampling times (

❈7)

Monitoring function

Enclosure rating (

❈8)

Ambient temperature

Relative humidity

Weight

2,400 times/s

Yes

IP64

0 to +50˚C (32 to 122˚F)

35% to 85% RH, No condensation

GaN green LED

❈1: The measuring accuracy is checked with a 1.0-mm-diameter round bar moved within a measuring area

of 2 x 4 mm.

❈2: The repeating accuracy is checked with 1.0-mm-diameter round bar located in the center of the

measuring area to check the outer diameter of the round bar with 512 averaging times and ±2σ set.

❈3: The measuring accuracy is checked with a 10-mm-diameter round bar moved within a measuring area

of 10 x 20 mm.

❈4: The repeating accuracy is checked with 10-mm-diameter round bar located in the center of the measur-

ing area to check the outer diameter of the round bar with 512 averaging times and ±2σ set.

❈5: The measuring accuracy is checked with a 20-mm-diameter round bar moved within a measuring area

of 20 x 40 mm.

❈6: The repeating accuracy is checked with 20-mm-diameter round bar located in the center of the measur-

ing area to check the outer diameter of the round bar with 512 averaging times and ±2σ set.

❈7: The number of sampling times per second will be 1,200 when the mutual interference prevention

function is used.

❈8: The Enclosure rating is not applicable to the cable connectors.

Optional Accessories

AC Power Supply Stand

Model

Applicable controller

Weight

Power supply voltage

Power consumption

Ambient temperature

Relative humidity

LS-S11

LS-7601

AC100 – 240V±10% 50/60Hz

110VA max

0 to +40˚C (32 to 104˚F)

35% to 85%RH, No condensation

Approx.1.7kg

Electrical

rating

Environment

resistance

TR Cables

Model

Cable length

Weight

OP-42182

1m

Approx. 50g

OP-42183

3m

Approx. 120g

❈ Up to two cables are connectable, provided

that the total length is 6 m or less.

Extension Cable (Cable between the
controller and measuring head)

Model

Cable length

Weight

LS-C3A

3m

Approx. 250 g

LS-C10A

10m

Approx. 700 g

LS-C30A

30m

Approx. 2,000 g

❈ Up to two cables are connectable, provided

that the total length is 40 m or less.

Camera Cable

Model

Cable length

Weight

LS-C3AM

3m

Approx. 150g

LS-C10AM

10m

Approx. 450g

LS-C30AM

30m

Approx. 1250g

❈ Up to two cables are connectable, provided