Statistical Sampling ON
This command starts data sampling for
statistical processing.
■
Statistical Sampling OFF
This command completes data sampling for
statistical processing.
External synchronization:
The LS-7600 Series completes statistical
sampling and starts statistical process-
ing.
Internal synchronization:
If the LS-7600 Series is in statistical
sampling operation, the LS-7600 Series
will cancel the statistical sampling
operation. If the LS-7600 Series is not in
statistical sampling operation, no statisti-
cal processing will be implemented.
LS
Output number
0 : OUT1+OUT2
1 : OUT1
2 : OUT2
Command
Response
O q
cr
O q
cr
LS
Output number
0 : OUT1+OUT2
1 : OUT1
2 : OUT2
Command
Response
R q
cr
R q
cr
Program No.
0~9, A~F
Command
Response
P W cr
P W
,
v
cr
LS
■
Program Number Selection
This command selects program numbers.
The command will be enabled if PANEL is
set as a P-SELECT environment setting
item.
Panel Lock ON/OFF
0 : OFF
1 : ON
2 : Confirm
Command
Response
LS
P L
,
w cr
cr
P L
,
w
Program No.
0~9, A~F
Command
Response
LS
P R cr
P R
,
v
cr
■
Program Number Confirmation
This command is used to confirm the
program number that has been currently
set.
The command will be enabled if PANEL is
set as a P-SELECT environment setting
item.
■
Key Lock ON/OFF
This command sets the key lock to ON or
OFF.