Schematic conventions – Kontron COMe Starterkit Eval T2 User Manual

Page 15

background image

Preface

1.10.

Schematic Conventions

Schematic examples are drawn with signal directions shown per the figure below. Signals that
connect directly to the COM Express connector are flagged with the text “CEX” in the off-page
connect symbol, as shown in Figure 1 below. Nets that connect to the COM Express Module are
named per the PICMG COM Express specification.

Figure 1: Schematic Conventions

Power nets are labeled per the table below. The power rail behavior under the various system
power states is shown in the table.

Table 3: Naming of Power Nets

Power Net

S0
On

S3
Suspend to
RAM

S4
Suspend to
Disk

S5
Soft Off

G3
Mechanical
Off

VCC_12V

12V

off

off

off

off

VCC_5V0

5V

off

off

off

off

VCC_3V3

3.3V

off

off

off

off

VCC_1V5

1.5V

off

off

off

off

VCC_2V5

2.5V

off

off

off

off

VCC_5V_SBY

5V

5V

5V

5V

off

VCC_3V3_SBY

3.3V

3.3V

3.3V

3.3V

off

VCC_RTC

3.0V

3.0V

3.0V

3.0V

3.0V

PICMG

®

COM Express

®

Carrier Board Design Guide

Rev. 2.0 / December 6, 2013

15/218

IC

CEX

CEX

CEX

CEX

OUTPUT FROM IC

INPUT TO IC

BIDIR SIGNAL

CEX

CEX

OUTPUT FROM IC TO COM EXPRESS

INPUT TO IC FROM COM EXPRESS

BIDIR SIGNAL TO / FROM COM EXPRESS

BIDIR SIGNAL TO / FROM COM EXPRESS

INPUT TO IC FROM COM EXPRESS

OUTPUT FROM IC TO COM EXPRESS

BIDIR SIGNAL

INPUT TO IC

OUTPUT FROM IC