Schematic conventions – Kontron COMe Starterkit Eval T2 User Manual
Page 15
Preface
1.10.
Schematic Conventions
Schematic examples are drawn with signal directions shown per the figure below. Signals that
connect directly to the COM Express connector are flagged with the text “CEX” in the off-page
connect symbol, as shown in Figure 1 below. Nets that connect to the COM Express Module are
named per the PICMG COM Express specification.
Figure 1: Schematic Conventions
Power nets are labeled per the table below. The power rail behavior under the various system
power states is shown in the table.
Table 3: Naming of Power Nets
Power Net
S0
On
S3
Suspend to
RAM
S4
Suspend to
Disk
S5
Soft Off
G3
Mechanical
Off
VCC_12V
12V
off
off
off
off
VCC_5V0
5V
off
off
off
off
VCC_3V3
3.3V
off
off
off
off
VCC_1V5
1.5V
off
off
off
off
VCC_2V5
2.5V
off
off
off
off
VCC_5V_SBY
5V
5V
5V
5V
off
VCC_3V3_SBY
3.3V
3.3V
3.3V
3.3V
off
VCC_RTC
3.0V
3.0V
3.0V
3.0V
3.0V
PICMG
®
COM Express
®
Carrier Board Design Guide
Rev. 2.0 / December 6, 2013
15/218
IC
CEX
CEX
CEX
CEX
OUTPUT FROM IC
INPUT TO IC
BIDIR SIGNAL
CEX
CEX
OUTPUT FROM IC TO COM EXPRESS
INPUT TO IC FROM COM EXPRESS
BIDIR SIGNAL TO / FROM COM EXPRESS
BIDIR SIGNAL TO / FROM COM EXPRESS
INPUT TO IC FROM COM EXPRESS
OUTPUT FROM IC TO COM EXPRESS
BIDIR SIGNAL
INPUT TO IC
OUTPUT FROM IC