P.008), P.010) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 78
6-8
FlexPak 3000 DC Drive Software Reference
The setting of
CT
TURNS
RATIO
can affect the value of
J
18
ARM
I
FB
RESISTOR
(P.395).
Check
J
18
ARM
I
FB
RESISTOR
(P.395) and the setting of the J18 jumper if you change
CT
TURNS
RATIO
.
MOTOR
RATED
ARM
AMPS
(P.008)
The rated armature
current from the
motor nameplate.
Parameter Range:
0 to 3000.0 amps
Default Setting:
8.0 amps
Parameter Type:
Configurable
OIM Menu Path(s):
Current Minor Loop (
CML
) -
CML
Feedback Scaling
Quick Start
The setting of
MOTOR
RATED
ARM
AMPS
can affect the value of
J
18
ARM
I
FB
RESISTOR
(P.395). Check
J
18
ARM
I
FB
RESISTOR
(P.395) and the setting of the J18 jumper if
you change
MOTOR
RATED
ARM
AMPS
.
!
ATTENTION: This parameter must be less than the motor rated armature
amps or drive current rating listed on the motor nameplate. If this is
configured incorrectly, overcurrent or excess heating of the motor could
result. Failure to observe this precaution could result in damage to, or
destruction of, the equipment.
CT
TURNS
RATIO
(P.010)
The drive current
transformer turns
ratio (Tp/Tn).
See Regulator board
replacement
instructions for
information on
determining the
CT
TURNS
RATIO
. This
parameter is not
restored if a Restore
Defaults is done.
Parameter Range:
139
208
417
833
2000
5230
OTHER
Default Setting:
n/a
(set at the factory based on the drive horsepower and
AC line voltage.
Parameter Type:
Configurable
OIM Menu Path(s):
Current Minor Loop (
CML
) -
CML
Feedback Scaling
!
ATTENTION: The
CT
TURNS
RATIO
parameter is used in the calculation
of the burden resistor value. Do not change this parameter from its
factory default value unless you are replacing the Regulator board.
Failure to observe this precaution could result in damage to, or
destruction of, the equipment.