Configuring the Speed/Voltage Loop
5-15
NEG
CURRENT
LIM
SEL
(P.224)
Selects the source for
the negative current
limit.
If
REGISTER
is
selected,
NEGATIVE
CURRENT
LIM
(P.006)
is used as the limit.
Parameter Range:
REGISTER
ANALOG
IN
1
ANALOG
IN
2
NETW
IN
REG
1
NETW
IN
REG
2
NETW
IN
REG
3
Default Setting:
REGISTER
Parameter Type:
Configurable
OIM Menu Path(s):
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Tuning
Current Minor Loop (
CML
) -
CML
Tuning
The I/O Expansion kit must be installed to use
ANALOG
IN
1 (terminals 50 and 51 on
the I/O Expansion board) or
ANALOG
IN
2 (terminals 52 and 53).
A network kit must be installed to select the network input registers (
NETW
IN
REG
1,
2, or 3). Note that the network input registers are updated only when Control
Source (P.000) is set to
NETWORK
and the network is active.
This parameter is affected by
NEG
CUR
LIM
INV
EN
(P.226).
NEG
CUR
LIM
INV
EN
(P.226)
Enables or disables
the negative current
limit inverter to the
speed loop PI block
low limit input.
Parameter Range:
DISABLED
ENABLED
Default Setting:
ENABLED
Parameter Type:
Configurable
OIM Menu Path(s):
Additional Parameters (listed by parameter number)
When this parameter is set to
ENABLED
,
POSITIVE
CURRENT
LIM
(P.005) and
NEGATIVE
CURRENT
LIM
(P.006) are restricted to positive values.
When this parameter is set to
DISABLED
, the range of
NEGATIVE
CURRENT
LIM
(P.006)
is restricted to negative values.
When you change this parameter value:
•
Alarm A00052 occurs.
•
The parameters
NEG
CURRENT
LIM
SEL
(P.224) and
POS
CURRENT
LIM
SEL
(P.223)
are automatically set to
REGISTER
.
•
NEGATIVE
CURRENT
LIM
(P.006) is inverted. For example, if
NEG
CUR
LIM
INV
EN
is
set to
ENABLE
and
NEGATIVE
CURRENT
LIM
is set to 150%
FLA
, changing
NEG
CUR
LIM
INV
EN
to
DISABLED
changes the value of
NEGATIVE
CURRENT
LIM
to –150%
FLA
.
Carefully check your current limit scheme and the values of
POSITIVE
CURRENT
LIM
(P.005) and
NEGATIVE
CURRENT
LIM
(P.006) to avoid unintended drive operation.