P.411) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 120
![background image](/manuals/581746/120/background.png)
11-4
FlexPak 3000 DC Drive Software Reference
DIG
OUT
2
SELECT
(P.411)
Selects the signal
used to drive digital
output 2 (terminals
68 and 69 on the I/O
Expansion kit).
Parameter Range:
LEVEL
DETECT
1
OUTPUT
LEVEL
DETECT
2
OUTPUT
IN
CURRENT
LIMIT
DRIVE
READY
NETW
COMM
STATUS
NETW
IN
REG
1 (bit 1)
NETW
IN
REG
2 (bit 1)
NETW
IN
REG
3 (bit 1)
Default Setting:
LEVEL
DETECT
2
OUTPUT
Parameter Type:
Configurable
OIM Menu Path(s):
Input/Output - Digital I/O
•
LEVEL
DETECT
1 or 2
OUTPUT
: The state of the selected level detector output drives
digital output 2. The signal is from the I/O Expansion kit digital output 1 or 2. See
chapter 12, Configuring the Drive to Use Level Detectors for information.
•
IN
CURRENT
LIMIT
: The armature in-current-limit signal, which indicates whether or
not the drive is operating at the maximum allowable current, drives digital
output 2. See
CML
REF
LIMIT
SELECT
(P.311), for information.
•
DRIVE
READY
: The drive-is-ready signal drives digital output 2. This signal
indicates that the drive will start when the next run or jog command is received.
•
NETW
COMM
STATUS
: The state of
NETW
COMM
STATUS
(P.908) drives digital
output 2. See chapter 10 for description.
NETW
IN
REG
1, 2, or 3: Bit 0 of
NETW
IN
REG
1 (P.905), 2 (P.906), or 3 (P.907) drives
digital output 2. A network kit must be installed to select the network input registers.
Note that the network input registers are updated only when Control Source (P.000)
is set to
NETWORK
and the network is active. See chapter 10 for description.