4.1
Configuring the Speed Reference Source Block
The speed reference can be either automatic or manual. An automatic (auto)
reference usually comes from a device such as a
PLC
or a network master. A manual
reference typically comes from a speed potentiometer or the
OIM
keypad. See the
OIM
manual for information on auto and manual references.
If an I/O Expansion kit is installed, the selected speed reference can be overridden by
a preset speed reference if selected (terminals 59 and 60). See section 4.1.7.
Table 4.1 shows the possible control source and reference source settings. It also
shows the display for the key indicator under
.
Most systems will use one primary reference source. For example, you might use a
network for your reference most of the time, but have the terminal strip reference
available for occasions when the network is not running or for troubleshooting.
The block diagram for the speed reference source is shown in figure 4.2.
!
ATTENTION: When switching from auto to manual or from manual to
auto, the drive will ramp to the reference level provided by the new source
at the rate specified by
ACCELERATION
TIME
(P.001) or
DECELERATION
TIME
(P.002). Be aware that an abrupt speed change might occur, depending
on the new reference and the rate specified in these parameters. Failure
to observe this precaution could result in bodily injury.
Table 4.1 – Effect of Control Source and Reference Settings
Control Source
Reference Set Through:
OIM
Key Indicator
OIM Reference Display
(Monitor Mode)
Units
KEYPAD
Automatic reference from the
terminal strip as set by
AUTO
REFERENCE
SELECT
(P.103)
AUTO
TERMBLK
REF
RPM
,
percentage,
or
user-defined
units
OIM
MANUAL
KEYPAD
REF
TERMBLK
(Regulator type is
speed/voltage)
Automatic reference from the
terminal strip as set by
AUTO
REFERENCE
SELECT
(P.103)
AUTO
TERMBLK
REF
Manual reference from the
terminal strip as set by
MANUAL
REF
SELECT
(P.106)
MANUAL
SERIAL
Automatic reference from the
terminal strip as set by
AUTO
REFERENCE
SELECT
(P.103)
AUTO
Serial device (
PC
)
MANUAL
SERIAL
REF
NETWORK
Network
AUTO
(Manual
not available)
NETWORK
REF
From
network
TERMBLK
(Regulator type is
current/torque)
Automatic reference from the
terminal strip as set by
AUTO
REFERENCE
SELECT
(P.103)
AUTO
(Manual
not available)
TORQUE
REF
MOTOR
LOAD
units