P.204), P.205), P.289) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 52
5-4
FlexPak 3000 DC Drive Software Reference
!
ATTENTION: The incorrect configuration of these parameters can cause
an overspeed condition. They must be configured by a qualified person
who understands the significance of configuring them. Failure to observe
this precaution could result in bodily injury.
ARM
VOLTAGE
GAIN
ADJ
(P.204)
Scales the armature
voltage signal after
the drive hardware
conditions the signal.
In most cases, this
parameter is set to
1.000.
Parameter Range:
0.750 to 1.250
Default Setting:
1.000
Parameter Type:
Tunable
OIM Menu Path(s):
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Feedback
Important: Adjust the zero point (
ARM
VOLTAGE
ZERO
ADJ
(P.205)) before
configuring gain.
ARM
VOLTAGE
ZERO
ADJ
(P.205)
Removes any offset
from the armature
voltage signal.
Parameter Range:
–200 to 200
Default Setting:
0
Parameter Type:
Tunable
OIM Menu Path(s):
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Feedback
If
ARMATURE
VOLTAGE
(P.289) is not equal to zero when the drive is stopped, adjust
ARM
VOLTAGE
ZERO
ADJ
up or down until
ARMATURE
VOLTAGE
(P.289) equals zero.
ARMATURE
VOLTAGE
(P.289)
Armature voltage
value after all
hardware and
software scaling but
before any
IR
compensation.
Parameter Range:
n/a
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Test Points
Speed/Voltage Loop (
SPD
) - Speed/Voltage Loop
(
SPD
) Tuning - Speed/Voltage Loop (
SPD
) Feedback
Current Minor Loop (
CML
) -
CML
Feedback Scaling -
SCR
Diagnostics - Armature Phase Fire Test