P.426) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 128
11-12
FlexPak 3000 DC Drive Software Reference
FREQ
OUT
ZERO
(P.426)
The frequency
generated when the
signal driving the
frequency output is
zero.
Parameter Range:
2.0 to
FREQ
OUT
FULL
SCALE
kHz
Default Setting:
2.0 kHz
Parameter Type:
Configurable
OIM Menu Path(s):
Input/Output - Frequency I/O
If the signal goes negative, the frequency output maintains the frequency set
by this parameter.
Table 11.1 – Options for Metering Parameters
Signal Selected
Full Scale Value
CML
FEEDBACK
(P.397)
CML
REFERENCE
(P.396)
CML
ERROR
(P.398)
SPD
LOOP
OUTPUT
(P.299)
(amps)
or
MAXIMUM
CURRENT
(% full load amps)
SPD
LOOP
FEEDBACK
(P.296)
SPD
LOOP
REFERENCE
(P.295)
SPD
LOOP
ERROR
(P.297)
SPEED
RAMP
OUTPUT
(P.199)
SPEED
RAMP
INPUT
TP
(P.198)
SPD
SOURCE
SELECT
OUT
(P.193)
TRIM
OUTPUT
(P.197)
ANALOG
TACH
FEEDBACK
(P.291)
PULSE
TACH
FEEDBACK
(P.292)
OCL
OUTPUT
(P.848)
TOP
SPEED
(
RPM
)
ARMATURE
VOLTAGE
(P.289)
MOTOR
RATED
ARM
VOLTS
(volts)
POWER
OUTPUT
watts
FIELD
REFERENCE
(P.590)
FIELD
FEEDBACK
(P.589)
MOTOR
HOT
FLD
AMPS
(amps)
OCL
REFERENCE
(P.845)
OCL
RAMP
OUTPUT
(P.846)
OCL
FEEDBACK
(P.847)
NETW
IN
REG
1 (P.905)
NETW
IN
REG
2 (P.906)
NETW
IN
REG
3 (P.907)
FULL
SCALE
4095 (counts)
ZERO
0
MOTOR RATED ARM AMPS
MAXIMUM CURRENT
100
------------------------------------------------------------
×
MOTOR RATED ARM VOLTS
MOTOR RATED ARM AMPS
×
MAXIMUM CURRENT
100
------------------------------------------------------------
Ч