Configuring the Speed Reference
4-27
JOG
OFF
DELAY
TIME
(P.121)
Specifies the
minimum delay
between removing
the jog input and
opening of the main
contactor in the drive.
Parameter Range:
0.0 to 10.0 seconds
Default Setting:
1.0 second
Parameter Type:
Configurable
OIM Menu Path(s):
Drive Reference - Drive Reference Configure
Releasing the jog input will not cause the contactor to open until the speed
feedback is less than or equal to
STOP
SPEED
THRESHOLD
or until the
JOG
OFF
DELAY
TIME
is exceeded, whichever occurs last.
This delay reduces the wear on the contactor when repeatedly opening and closing
the
JOG
input in a short period of time.
JOG
RAMP
OUTPUT
(P.294)
The jog reference
value immediately
after the jog ramp
function.
Parameter Range:
n/a
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Drive Reference - Drive Reference Test Points
JOG
SPEED
1 (P.012)
The operating speed
while the drive is
jogging if
DIG
IN
0
SELECT
(P.428) is set
to
JOG
SPEED
SELECT
and digital input 0
(terminal 12 on the
Regulator board) is
off.
Parameter Range:
0 to
MAXIMUM
SPEED
(
RPM
or user-defined units)
Default Setting:
250
RPM
Parameter Type:
Tunable
OIM Menu Path(s):
Drive Reference - Drive Reference Configure
Quick Start
JOG
SPEED
2 (P.017)
The operating speed
when the drive is
jogging if
DIG
IN
0
SELECT
(P.428) is set
to
JOG
SPEED
SELECT
and digital input 0
(terminal 12 on the
Regulator board) is
on.
Parameter Range:
0 to
MAXIMUM
SPEED
(
RPM
or user-defined units)
Default Setting:
250
RPM
Parameter Type:
Tunable
OIM Menu Path(s):
Additional Parameters (listed by parameter number)