5-18
FlexPak 3000 DC Drive Software Reference
SPD
LOOP
OUTPUT
(P.299)
Speed loop
PI
block
output value.
Parameter Range:
n/a
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
SPD
- Speed/Voltage Loop (
SPD
) Test Points
Current Minor Loop (
CML
) -
CML
Test Points
SPD
LOOP
PI
INIT
SEL
Selects the source for
the initial value of the
speed loop
PI
block
when
CONTROL
SOURCE
SELECT
is set
to
NETWORK
.
If
CONTROL
SOURCE
SELECT
is not set to
NETWORK
,
SPD
LOOP
PI
INIT
SEL
is forced to
ZERO
.
Parameter Range:
0 =
ZERO
1 =
SPD
LOOP
PI
INIT
VAL
2 =
ANALOG
MAN
TRIM
REF
(P.194)
Default Setting:
0
Parameter Type:
Configurable
OIM Menu Path(s):
This parameter is available over the network, It
cannot be viewed through the
OIM
.
Refer to the appropriate network communication manual for register map
assignments.
SPD
LOOP
PI
INIT
VAL
The initial value of the
speed loop
PI
block
when
CONTROL
SOURCE
SELECT
is set
to
NETWORK
and
SPD
LOOP
PI
INIT
SEL
is set
to 1 (
SPD
LOOP
PI
INIT
VAL
).
Parameter Range:
–32768 to 32767
Default Setting:
0
Parameter Type:
Tunable
OIM Menu Path(s):
This parameter is only available over the network, It
cannot be viewed through the
OIM
.
This parameter is forced to 0 if
CONTROL
SOURCE
SELECT
is not set to
NETWORK
.
Refer to the appropriate network communication manual for register map
assignments.