P.904), 1 (p.905), 2 (p.906) – Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 111: 3 (p.907)

Configuring a Network
10-5
NETW
OUT
REG
3
SELECT
(P.904)
Selects the
parameter to be
monitored.
Parameter Range:
–32768 to 32767
Default Setting:
0
Parameter Type:
Tunable
OIM Menu Path(s):
Network Communications
Select the parameter to monitor by configuring the parameter number. For example,
setting this parameter equal to 588 will write the value of parameter
FIELD
DELTA
(P.588) to the installed network register.
NETW
IN
REG
1 (P.905)
Indicates the value
being written by the
network master.
Parameter Range:
–32768 to 32767
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Network Communications
For the AutoMax network, this parameter writes to Drop_1, register 34. For the
ControlNet network, this parameter writes to file address N11:10.
NETW
IN
REG
2 (P.906)
Indicates the value
being written by the
network master.
Parameter Range:
–32768 to 32767
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Network Communications
For the AutoMax network, this parameter writes to Drop_1, register 35. For the
ControlNet network, this parameter writes to files address N11:11.
NETW
IN
REG
3 (P.907)
Indicates the value
being written by the
network master.
Parameter Range:
–32768 to 32767
Default Setting:
n/a
Parameter Type:
Output
OIM Menu Path(s):
Network Communications
For the AutoMax network, this parameter writes to Drop_1, register 36. For the
ControlNet network, this parameter writes to file address N11:12.