Rockwell Automation FlexPak 3000 Digital DC Drive Version 4.3 User Manual
Page 174
C-12
FlexPak 3000 DC Drive Software Reference
OCL
TYPE
3
POSN
REG
EN
(P.814)
•
DISABLED
•
ENABLED
DISABLED
OPEN
SCR
SENSITIVITY
(P.600)
0 to 100%
50%
OPEN
SCR
TRIP
THRESH
(P.601)
800 to 4000
1600
PHASE
FIRE
TEST
DELTA
(P.309)
0 to 180
DEGREE
0
DEGREE
PHASE
FIRE
TST
BRIDGE
(P.310)
•
OFF
•
ON
OFF
PHASE
LOSS
DETECT
EN
(P.609)
•
DISABLE
•
ENABLE
ENABLE
PLL
MAXIMUM
ERROR
(P.308)
2 to 1000
µ
sec
2
µ
sec
POS
CURRENT
LIM
SEL
(P.223)
•
REGISTER
•
ANALOG
IN
1
•
ANALOG
IN
2
•
NETW
IN
REG
1
•
NETW
IN
REG
2
•
NETW
IN
REG
3
REGISTER
POSITIVE
CURRENT
LIM
(P.005)
0 to
MAXIMUM
CURRENT
(%
FLA
)
150 %
FLA
PRESET
SPEED
1 (P.117)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PRESET
SPEED
2 (P.118)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PRESET
SPEED
3 (P.119)
MINIMUM
SPEED
to
MAXIMUM
SPEED
(
RPM
or user-defined units)
250
RPM
PULSE
TACH
PPR
(P.207)
18 to 2500
PPR
18
PPR
PULSE
TACH
QUADRATURE
(P.208) •
ON
•
OFF
ON
RAMP
STOP
DECEL
TIME
(P.018)
0.1 to 300.0 seconds
5.0 seconds
REVERSE
DISABLE
(P.015)
•
OFF
•
ON
OFF
S
-
CURVE
ROUNDING
(P.014)
0 to 50%
0%
SELF
TUNE
BRIDGE
(P.220)
•
FORWARD
•
REVERSE
FORWARD
SELF
TUNE
FIELD
RANGE
(P.218)
0.90 to 5.00
1.00
Table C.1 – Parameter Settings Quick Reference Table (Continued)
Parameter
Parameter Selection/
Adjustment Range
Initial Factory
Setting (Default)
Your Data
Date
Setting