Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 65
3–7
Programming Terminal
Publication 1397-5.0 — June, 2001
Program and Display Modes
or
or
or
1. The Display and Program modes allow
access to the parameters for viewing or
programming.
A. From the Status Display, press Enter (or
any key). “Choose Mode” will be
shown.
B. Press the Increment (or Decrement) key
to show “Program” (or “Display”).
C. Press Enter.
D. Press the Increment (or Decrement) key
until the desired group is displayed.
E. Press Enter.
F. Press the Increment (or Decrement) key
to scroll to the desired parameter.
Choose Mode
Display
Choose Mode
Program
Choose Group
Metering
Anlg In 1
+0 RPM
or
Bit ENUMs
Masks
Logic Mask
Terminal Blk
X1111111
Bit ENUMS (16 character text strings) will
be displayed to aid interpretation of bit
parameters.
G. Select a bit parameter with the Increment
(or Decrement) keys.
H. Press the SELect key to view the ENUM
of the first bit. Pressing this key again
will move the cursor to the left one bit.
A blinking underline cursor will indicate
that you are in the Display mode or that a
Read Only parameter has been accessed.
A flashing character will indicate that the
value can be changed.
Individual bits of a Read/Write parameter
can be changed in the same manner.
Pressing the SELect key will move the
cursor (flashing character) one bit to the
left. That bit can then be be changed by
pressing the Increment/Decrement keys.