Options – Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 18

1–10
Introduction
Publication 1397-5.0 — June, 2001
ББББББББББ
ББББББББББ
Name
БББББББББББББББ
БББББББББББББББ
Description
БББББ
БББББ
I/M Number
ББББББББББ
ББББББББББ
ББББББББББ
115 V AC Control Interface
All Horsepowers
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Converts customer-supplied 115 V AC signals to 24 V DC for operating a
1397. Mounts separately on the panel or can be mounted in the bottom
of a NEMA Type 1 enclosed drive.
БББББ
БББББ
БББББ
1397-5.18
ББББББББББ
ББББББББББ
230 V AC Conversion
БББББББББББББББ
БББББББББББББББ
Allows conversion of the 460 V AC 1397 to a 230 V AC 1397 at one-half
the 460 V AC horsepower rating.
БББББ
БББББ
1397-5.16
ББББББББББ
ББББББББББ
Б БББББББББ
ББББББББББ
A-C Line Disconnect
3 – 60 HP @ 460V
1 – 30HP @ 230V
7 – 100A @ 380/415VAC
БББББББББББББББ
БББББББББББББББ
Б ББББББББББББББ
БББББББББББББББ
Allows the three-phase line to be disconnected at the drive. Molded
case switch that mounts on the chassis of the drive or NEMA Type 1
enclosure.
БББББ
БББББ
БББББ
БББББ
1397-5.11
ББББББББББ
ББББББББББ
Б БББББББББ
Б БББББББББ
ББББББББББ
Dynamic Braking
БББББББББББББББ
БББББББББББББББ
Б ББББББББББББББ
Б ББББББББББББББ
БББББББББББББББ
Provides the hardware, including braking grids, needed to provide
dynamic braking on stop. Supplied in a NEMA Type 1 enclosure.
The 1397–DB–A and 1397–DB–B series allow the kit to be panel
mounted. These kits include the resistor grid assembly and contactor.
The customer must supply fused 115 V AC.
БББББ
БББББ
БББББ
БББББ
БББББ
1397-5.15
ББББББББББ
ББББББББББ
ББББББББББ
Enhanced Field Supply
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Provides electronic field trim, field economy, and the ability to supply
240V field voltage and other special voltages. This kit replaces the
standard field supply.
БББББ
БББББ
БББББ
1397-5.24
ББББББББББ
ББББББББББ
Б БББББББББ
Б БББББББББ
ББББББББББ
Regulated Field Supply
Supplied as standard on:
400 – 600HP @ 460V
150HP @ 460V
75 HP @ 230V and up
265 & 521 ADC @ 380/415 VAC
БББББББББББББББ
БББББББББББББББ
Б ББББББББББББББ
Б ББББББББББББББ
БББББББББББББББ
Provides field economy, as well as pre-weakening of the field using a
fixed reference or field weakening for above base speed operation.
Tachometer feedback is required with this kit. This kit replaces the
standard field supply.
БББББ
БББББ
БББББ
БББББ
БББББ
1397-5.17
ББББББББББ
ББББББББББ
Blower Motor Starter
БББББББББББББББ
БББББББББББББББ
Provides a fused A-C starter with adjustable overload and interlocking
for control of three phase blower motor used to cool the DC motor.
БББББ
БББББ
1397-5.20
ББББББББББ
ББББББББББ
ББББББББББ
Expansion I/O Module
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Mounts on the 1397 chassis and gives the drive additional analog,
frequency, and digital I/O capability.
БББББ
БББББ
БББББ
1397-5.19
ББББББББББ
ББББББББББ
Pulse Encoder Interface Card
All Horsepowers
БББББББББББББББ
БББББББББББББББ
Allows for digital pulse encoder speed feedback
БББББ
БББББ
1397-5.13
ББББББББББ
ББББББББББ
AC Tachometer Interface Card
All Horsepowers
БББББББББББББББ
БББББББББББББББ
Allows for AC tachometer speed feedback
БББББ
БББББ
1397-5.22
ББББББББББ
ББББББББББ
ББББББББББ
AC Line Disconnect
75 – 150 HP @ 460V
40 – 75 HP @ 230V
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Allows the three phase line to be disconnected at the drive.
БББББ
БББББ
БББББ
1397-5.21
ББББББББББ
ББББББББББ
Б БББББББББ
ББББББББББ
AC Line Disconnect
200 – 300 HP @ 460V
100 – 150 HP @ 230V
521 ADC @ 380/415 VAC
БББББББББББББББ
БББББББББББББББ
Б ББББББББББББББ
БББББББББББББББ
Allows the three phase line to be disconnected at the drive.
БББББ
БББББ
БББББ
БББББ
1397-5.27
ББББББББББ
ББББББББББ
Inverting Fault Circuit Breaker
400–600 HP
БББББББББББББББ
БББББББББББББББ
Allows high inertia loads on regenerative 1397 drives.
БББББ
БББББ
1397-5.29
ББББББББББ
ББББББББББ
ББББББББББ
AC Line Disconnect
400 – 600 HP @ 460V
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Allows the three phase line to be disconnected at the drive.
БББББ
БББББ
БББББ
1397-5.30
ББББББББББ
ББББББББББ
AC Line Filter Kit
600 HP @ 460V
БББББББББББББББ
БББББББББББББББ
Allows power transformer greater than 2300V RMS to be applied to the
drive.
БББББ
БББББ
1397-5.31
ББББББББББ
ББББББББББ
ББББББББББ
Dynamic Braking Resistor Assembly
Lifting Instructions 250–600HP
БББББББББББББББ
БББББББББББББББ
БББББББББББББББ
Provides instructions for properly attaching and lifting Dynamic Braking
Kits.
БББББ
БББББ
БББББ
1397-5.32
Options