beautypg.com

Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 162

background image

5–52

Programming Parameters

Publication 1397-5.0 — June, 2001

OUTPUT CONFIG

[Anlg Out 1 Src] — P.145

Selects the drive testpoint that will source
meter output 1 (terminals 24 and 25 on the
regulator board).

Display/Drive Units:

Numeric/Text

Parameter Range:

0 = Cur Lp Fdbk

11 = Arm Volt

1 = Cur Loop Ref

12 = ATach Fdbk

2 = Cur Loop Err

13 = Encoder Fdbk

3 = Spd Loop Fdbk

14 = Zero

4 = Spd Lp Ref

15 = Full Scale

5 = Spd Lp Error

16 = Power Output

6 = Spd Lp Out

17 = OCL Ref

7 = Spd Ramp Out

18 = OCL Ramp Out

8 = Spd Ramp In

19 = OCL Feedback

9 = Spd Src Out

20 = OCL Output

10 = Trim Output

21 = Field Ref
22 = Field Fdbk

Note: See Table A below for Full Scale Values

Default Setting:

0 [Cur Lp Fdbk]

Minimum Value:

0 [Cur Lp Fdbk]

Maximum Value:

22 [Field Fdbk]

Parameter Type:

Tunable

Group:

Output — Output Config

Table A – Source Signal Values

Signal Selected

Full Scale Value

[Cur Loop Fdbk] — P.006
[Cur Loop Ref] — P.008
[Cur Loop Error] — P.007
[Spd Loop Output] — P.024

[Motor Arm Amps (P.45)]

× Maximum Current (P.40)

100

= FULL SCALE VALUE

[Spd Loop Fdbk] — P.022
[Spd Loop Ref] — P.025
[Spd Loop Error] — P.021
[Spd Ramp Output] — P.028
[Spd Ramp Input Tp] — P.027
[Spd Sc Output] — P.026
[Trim Output] — P.030
[Analog Tach Fdbk] — P.194
[Encoder Fdbk] — P.189
[OCL Output] — P.018

Top Speed

[Armature Voltage] — P.005

[Motor Arm Volts]

Power Output

[Motor Arm Volts]

× [Motor Arm Amps] × Maximum Current

100

[Fld Reference] — P.280
[Field Feedback] — P.010

[Motor Field Amps]

[OCL Reference TP] — P.020
[OCL Ramp Output] — P.019
[OCL Feedback] — P.017

4095