Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 162
5–52
Programming Parameters
Publication 1397-5.0 — June, 2001
OUTPUT CONFIG
[Anlg Out 1 Src] — P.145
Selects the drive testpoint that will source
meter output 1 (terminals 24 and 25 on the
regulator board).
Display/Drive Units:
Numeric/Text
Parameter Range:
0 = Cur Lp Fdbk
11 = Arm Volt
1 = Cur Loop Ref
12 = ATach Fdbk
2 = Cur Loop Err
13 = Encoder Fdbk
3 = Spd Loop Fdbk
14 = Zero
4 = Spd Lp Ref
15 = Full Scale
5 = Spd Lp Error
16 = Power Output
6 = Spd Lp Out
17 = OCL Ref
7 = Spd Ramp Out
18 = OCL Ramp Out
8 = Spd Ramp In
19 = OCL Feedback
9 = Spd Src Out
20 = OCL Output
10 = Trim Output
21 = Field Ref
22 = Field Fdbk
Note: See Table A below for Full Scale Values
Default Setting:
0 [Cur Lp Fdbk]
Minimum Value:
0 [Cur Lp Fdbk]
Maximum Value:
22 [Field Fdbk]
Parameter Type:
Tunable
Group:
Output — Output Config
Table A – Source Signal Values
Signal Selected
Full Scale Value
[Cur Loop Fdbk] — P.006
[Cur Loop Ref] — P.008
[Cur Loop Error] — P.007
[Spd Loop Output] — P.024
[Motor Arm Amps (P.45)]
× Maximum Current (P.40)
100
= FULL SCALE VALUE
[Spd Loop Fdbk] — P.022
[Spd Loop Ref] — P.025
[Spd Loop Error] — P.021
[Spd Ramp Output] — P.028
[Spd Ramp Input Tp] — P.027
[Spd Sc Output] — P.026
[Trim Output] — P.030
[Analog Tach Fdbk] — P.194
[Encoder Fdbk] — P.189
[OCL Output] — P.018
Top Speed
[Armature Voltage] — P.005
[Motor Arm Volts]
Power Output
[Motor Arm Volts]
× [Motor Arm Amps] × Maximum Current
100
[Fld Reference] — P.280
[Field Feedback] — P.010
[Motor Field Amps]
[OCL Reference TP] — P.020
[OCL Ramp Output] — P.019
[OCL Feedback] — P.017
4095