Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual

Page 129

background image

5–19

Programming Parameters

Publication 1397-5.0 — June, 2001

METERING

[Spd Loop Error] — P.021

The speed loop error signal, which represents
the difference between the [Spd Loop Ref]
and the [Spd Loop Fdbk] signals.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–8190

Maximum Value:

8190

[Spd Loop Fdbk] — P.022

An output that represents the selected
speed/voltage loop drive feedback value after
all scaling.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–4095

Maximum Value:

4095

[Spd Loop Lag Out] — P.023

An output representing the value immediately
after the Speed Loop Lag function.

Display/Drive Units:

RPM

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–4095

Maximum Value:

4095

[Spd Loop Output] — P.024

Speed Loop PI function output value to the
Current Loop.

Display/Drive Units:

AMPS

Group:

Metering

Type:

Factory Default:

0

Minimum Value:

–1440.0

Maximum Value:

1440.0