Programming Parameters
Publication 1397-5.0 — June, 2001
OWNERS
[Flt Reset Owner] — P.219
This parameter displays which parameter is
currently resetting a fault.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
0000000000000000
Factory Default:
0000000000000000
Maximum Value:
0000000001111111
[MOP Owner] — P.220
This parameter displays which adapters are
currently issuing increases or decreases in
MOP Command Frequency.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
0000000000000000
Factory Default:
0000000000000000
Maximum Value:
0000000001111111
[Local Owner] — P.221
This parameter displays which adapter has
requested exclusive control of all drive logic
functions. If an adapter is in local lockout, all
other functions (except stop) on all other
adapters are locked out and non–functional.
Local control can only be obtained when the
drive is not running.
Display/Drive Units:
Numeric/Text
Parameter Range:
Bit # Enum Text
0 = Terminal Block
1 = Adapter 1
2 = Adapter 2
3 = Adapter 3
4 = Adapter 4
5 = Adapter 5
6 = Adapter 6
Parameter Type:
Read Only
Group:
Owners
Minimum Value:
0000000000000000
Factory Default:
0000000000000000
Maximum Value:
0000000001111111