Rockwell Automation 1397 DC Drive Firmware 2.xx User Manual
Page 141
5–31
Programming Parameters
Publication 1397-5.0 — June, 2001
ADV SETUP
[Pos Cur Lim Src] — P.069
Selects the source for the positive current
limit.
If Register is selected, the reference is [Pos
Cur Lim].
The I/O Expansion kit must be installed to
use Analog In 3 (terminals 50 and 51 on the
I/O Expansion board), Analog In 4 (terminals
52 and 53), or Frequency In (terminals 39,
40, and 41).
Display/Drive Units:
Numeric/Text
Parameter Range:
0 = Register
1 = Analog In 3
2 = Analog In 4
3 = Frequency In
4 = Adapter 1
5 = Adapter 2
6 = Adapter 3
7 = Adapter 4
8 = Adapter 5
9 = Adapter 6
Default Setting:
Register
Parameter Type:
Configurable
Group:
Advanced Set–Up
Factory Default:
0
Minimum Value:
0
Maximum Value:
9
[Neg Cur Lim Src] — P.070
Selects the source for the negative current
limit. If Register is selected, [Neg Cur Lim] is
used as the limit.
The analog input choices are only available if
the I/O Expansion kit is installed. The
Network choices are only available if the
Network Option kit is installed.
Display/Drive Units:
Numeric/Text
Parameter Range:
0 = Register
1 = Analog In 3
2 = Analog In 4
3 = Frequency In
4 = Adapter 1
5 = Adapter 2
6 = Adapter 3
7 = Adapter 4
8 = Adapter 5
9 = Adapter 6
Default Setting:
Register
Parameter Type:
Configurable
Group:
Advanced Setup
Factory Default:
0
Minimum Value:
0
Maximum Value:
9
Note: Default is zero for non-regenerative drives, if [Feedback Type] is set to AC Tach, or if [Feedback Type] is set to Encoder and [Encoder
Quad] is off.